Client reported that sequencer began to play automatically while DJ was doing live show in live-assist mode at 8:00:32 in Oct 28.

We checked the debug file, no any “fade_n_go” record at that time. But there is “DO_NEXT_ITEM_LOAD”, in my memory, this message will only show before hard ETM, but the nearest hard ETM was executed at 07:59:47, the next hard ETM will be executed at 08:59:47.

1
2
3
4
5
6
7
8
0-28 08:00:32.199 | Seq    | SEQUENCER       | CQ881-FM        | Start of processing Resync for EventId: 542647 Event: EXACT_TIME_MARKER Stop Playing Items: True
0-28 08:00:32.199 | Seq    | SEQUENCER       | CQ881-FM        | Trying to start the next item after a hard etm Id: 542647 station setting is set to start next event after hard etm
0-28 08:00:32.199 | Seq    | SEQUENCER       | CQ881-FM        | Adding action to the BreakFromLoopActions, description: SetFirstCuedEventAsPlayable
0-28 08:00:32.199 | Seq    | SEQUENCER       | CQ881-FM        | Adding action to the EndOfLoopActions, description: SetFirstCuedEventAsPlayable
0-28 08:00:32.199 | Seq    | SEQUENCER       | CQ881-FM        | End of processing Resync for EventId: 542647 Event: EXACT_TIME_MARKER, Items Resynced: 0
0-28 08:00:32.414 | Seq    | SEQUENCER       | CQ881-FM        | START - Sequencer DB Thread performing action: DO_NEXT_ITEM_LOAD
0-28 08:00:32.414 | Seq    | SEQUENCER       | CQ881-FM        | Start of LoadNextItems, MinGroupSeq: 8  MinSeq: 21  MaxEvents: 15  Min Date: 2020/10/28 0:00:00  Check next day: True  Go till hard timed: True  Load For Splits: False  MaxGetItems: 182
0-28 08:00:32.860 | Seq    | SEQUENCER       | CQ881-FM        | End of LoadNextItems, return count: 75 Time to do fill: 446(ms)

The same problem happened again at 13:03:42 again. They are using Zetta 4.19.2.370, our engineer is on site, please take a look, much appreciate.